Online DCS100 OPWS Data Sheet for Potomac Module Crew

These are the setting the Potomac Module Crew uses on DSC100 master and DCS100 booster. The settings have been used since about 1996 with few minor changes over the years.

At some trains show, we do disable OPWS 20 for large layout size.

OPWS FAC PMC Function oF OPWS Notes
1 t t Reserved, DO NOT CHANGE. Set to always "thrown"
2 t t Reserved, DO NOT CHANGE. Set to always "thrown".
To use as booster, set to "close".
Note 1
3 t c This DCS100's booster is AUTO REVERSING.
For non Auto Reversing, set to "close".
Note 2
4 t t Reserved, DO NOT CHANGE. Set to always "thrown"
5 c c Command station master mode always make "closed".
To use as booster, set to "thrown"
Note 1
6 t t Reserved, DO NOT CHANGE. Set to always "thrown"
7 t t Reserved, DO NOT CHANGE. Set to always "thrown"
8 t t Reserved, DO NOT CHANGE. Set to always "thrown"
9 t t Allows Motorola trinary switch packet command echo for switches 1-256
10 t t Expand trinary switches echo range packet from 1-64 to 1-256 when OPSW#9 is "closed"
11 t t Make trinary switches 57-64 long duration ON period when OPSW#9 is "closed"
12 t t Motorola trinary/AC digital mobile decoder address 1-80 allowed
13 t t Loco purge time extended from 200 seconds to 600 seconds
14 t t Loco purge is disable
15 t t Purging will force a loco to STOP or 0 Speed
16 t t Reserved, DO NOT CHANGE. Set to always "thrown"
17 t t Automatic advanced decoder assisted [FX] consists are disabled
18 t t Extend the DCS100 booster short circuit shutdown time from 1/8 to 1/2 second
19 t t Reserved, DO NOT CHANGE. Set to always "thrown"
20 t t Disabled address 00 or analog stretching for conventional locos
21 t t OPSW#21 to OPSW#23: set the global system default type for NEW loco selection Note 3
22 t t OPSW#21 to OPSW#23: set the global system default type for NEW loco selection Note 3
23 t c OPSW#21 to OPSW#23: set the global system default type for NEW loco selection Note 3
24 t t Reserved, DO NOT CHANGE. Set to always "thrown"
25 t c Disable aliasing in this DCS100 Note 4
26 t t Enable routes in this DCS100
27 t t Disable normal switch commands. a.k.a the Bushby bit
28 t t Disable DS54 interrogate command at GPON
29 t t Reserved, DO NOT CHANGE. Set to always "thrown"
30 t t Reserved, DO NOT CHANGE. Set to always "thrown"
31 t t Means meter route / switch output rate when not trinary
32 t t Reserved, DO NOT CHANGE. Set to always "thrown"
33 t c Allow track power to restore to prior state at power on
34 t c Allow track to power up at run state, if was run prior to power on
35 t t Reserved, DO NOT CHANGE. Set to always "thrown"
36 t t Reset / clear / erase all mobile decoder information & consists
37 t t Erase / clear all routes
38 t t Erase / clear the loco roster
39 t t Clear all internal memory states, including section. OPSW#36, 37, 38 clear Note 5
40 t t Reserved, DO NOT CHANGE. Set to always "thrown"
41 t t Diagnostic click when valid Loconet commands incoming, & routes being output
42 t t Disable 3 beeps on Purging a loco
43 t t Disable Loconet Update of command station's track status
44 t c Expand slot refresh area from 22 (Big Boy compatible) to 120
45 t t Disable reply for switch state request
46 t t Reserved, DO NOT CHANGE. Set to always "thrown"
47 t t Program track is brake signal generator when not in Programming Mode
48 t t OPSW#48 to OPSW#999 are always to be "thrown" unless otherwise noted!

To return to top of page.

Notes:

To return to top of page.